Test Report and customer feedback SPECTRAN Analyzer: |
|
Topics (please
select): TEST REPORT: Detailed SPECTRAN Rev2 measurements at the
Aaronia Lab with Rohde & Schwarz
SMJ100A: CUSTOMER FEEDBACK: REFERENCES (Current orders): |
| Detailed test report (74 pages) on the SPECTRAN Rev2: |
![]() |
From 21.4. to 28.4.2006 the test lab of the CETECOM ICT
Services GmbH, a company of the RWTÜV AG, made a
very detailed test report about the SPECTRAN
HF-2025E. The SPECTRAN has been tested for compliance of
measurement values in comparison with industrial broadband
field probes and professional spectrum analyzer within lab
and outdoor. Lots of test have been done to prove the use
and measurement accuracy on DECT, WLan, UMTS and GSM. The final (original) statement of the CETECOM:
"...sufficient measurement accuracy during the measurement
of RMS signals strength of pulsed and unpulsed signals as
required by EMF-test specification. It (HF-2025E) can
therefore be applied for EMCE measurements of all tested
signal types." Download the complete test
report incl. lots of pictures as PDF file (74
pages): |
| Test Report on the SPECTRAN Rev2 level accuracy (in german): |
![]() |
The "EMC Transferstelle" at the "FH Koblenz" made a test
report on the level accuracy of a SPECTRAN HF-2025E. This
report shows the good accuracy of max. 3,2dB at the
TOTAL range of a HF-2025E from -80dBm to 0dBm within the
used frequency band (german only). Download the complete test
report with pictures as PDF: |
| Detailed SPECTRAN Rev2 measurements at the Aaronia Lab with Rohde & Schwarz SMJ100A Vector Signal Generator |
|
This measurements have been made with a SPECTRAN
HF-2025E. We made the test with our own test equipment using a professional VECTOR Signal-Generator with AWG (Arbitrary Waveform Generator) from Rohde & Schwarz type SMJ100A. Our generator is equipped with the following Options:
About the setup: |
|
The System CALIBRATION
We used a non modulated test signal to calibrate the
SPECTRAN at exactly -20dBm at 2GHz. The SPECTRAn shows the
signal with very accurate -20dBm (-20dBm). Please note that
the SPECTRAN only offers a full digit dBm display. That's
why we also use a notebook with the LCS software. The
LCS-Software offers a much higher resolution and offers a
1/100 dBm resolution. The LCS software shows real power
with -19,98dBm. Only 0,02dB failure. We can live
with that ;-) |
|
Measurement of GSM (GSM900, GSM1800 and GSM1900) SPECTRAN shows a perfect GSM-Signal level (-20dBm). The
LCS-Software shows -19,59dBm. |
|
Measurement of 3GPP (UMTS) SPECTRAN shows a perfect 3GPP-Signal (-20dBm). The
LCS-Software shows -20,08dBm. |
|
Measurement of CDMA2000 SPECTRAN shows a slightly to high level of the
CDMA2000-Signal of 2dB (-18dBm). The LCS-Software shows
-17,89dBm. |
|
Measurement of WLAN 802.11b with PBCC & CCK-Modulation SPECTRAN shows a 3dB to high level of the WLan 802.11b
Signal with PBCC Modulation (-17dBm). The
LCS-Software shows -17,37dBm. SPECTRAN shows a 3dB to high level of the WLan 802.11b
Signal with CCK Modulation (-17dBm). The
LCS-Software shows -17,09dBm. |
|
Measurement of WLAN 802.11g with Frame-Test SPECTRAN shows a 3dB to high level at Framed WLan
802.11g (-17dBm). The LCS-Software shows -17,38dBm. SPECTRAN shows a slightly to high level at
Unframed WLan 802.11g (-18dBm). The LCS-Software
shows -17,69dBm. |
|
Measurement of WiMAX with OFDM & OFDMA-Modulation SPECTRAN shows a slightly to high level at WiMAX 802.16
Signals with OFDM Modulation (-19dBm). The
LCS-Software shows -18,82dBm. SPECTRAN shows a perfect signal level of WiMAX 802.16
with OFDMA Modulation (-20dBm). The LCS-Software
shows -19,71dBm an. |
|
Measurement of GPS SPECTRAN shows a perfect signal level of the GPS-Signal
(-20dBm). The LCS-Software shows -20,41dBm an. |
| Some customer feedback about the SPECTRAN in English (incl. original "type error"): |
|
Steve E., USA: I just wanted to let you know how pleased I am with your model 6060 overall, and your warranty and upgrade policy in particular. I think it says a lot abtut a Company when they back their products like this. I wish more companies did. ... In thirty plus years of doing technical stuff, I've never once felt the need or been compelled to compliment a manufacturer of hardware and software. Until now. Once again, very well done. Richard B., USA: Justin B., USA: Martyn K., Spain: Roy R., United Kingdom: Greg K., USA: Ulrich H., Netherlands: Toshi T., Japan: Richard B., USA: Kevin M., USA: |
| SPECTRAN REFERENCES (Current orders): |
|
![]() |
Aaronia AG,
Gewerbegebiet Aaronia AG, D-54597 Euscheid, Germany Tel. ++49(0)6556-93033, Fax ++49(0)6556-93034 Email:mail@aaronia.de URL:www.spectran.com |
Are registrated trademarks of Aaronia AG |
| Back to Aaronia website |